FALEX TIMKEN

One of the oldest and the first commercially available tester (1935) for evaluating load carrying capacity of extreme pressure lubricants.  Contrary to the Four Ball test, this system uses a line contact with moderate contact pressures to evaluate the scoring limit of oils and greases.

A rotating steel bearing race (“cup”) runs at ~800 rpm against a stationary steel block under increasing load conditions until a score mark appears; the load just before scoring is the OK Load.

More info from manufacturer

 Standards and methods

  • ASTM D2509 - Standard Test Method for Measurement of Load-Carrying Capacity of Lubricating Grease (Timken Method)
  • ASTM D2782 - Standard Test Method for Measurement of Extreme-Pressure Properties of Lubricating Fluids (Timken Method)
logo

Falex Tribology

Wingepark 23B
Rotselaar B-3110 BELGIUM

Falex Application Center for industrial Tribology

VAT : BE0466260885

Follow Us: